ASTM A938 PDF

ASTM A and ISO address the requirements for simple torsion (twist) testing of metallic wire. Both testing standards require that a wire specimen be. This standard is issued under the fixed designation A ; the number 1 This test method is under the jurisdiction of ASTM Committee A01 on Steel,. Stainless . ASTM A covers torsion testing of wire. ASTM A provides knowledge of the ductility of a wire when under torsion loading. A torsional test machine with.

Author: Babar Akiktilar
Country: Bosnia & Herzegovina
Language: English (Spanish)
Genre: Environment
Published (Last): 20 February 2010
Pages: 43
PDF File Size: 18.35 Mb
ePub File Size: 4.29 Mb
ISBN: 712-5-91874-397-2
Downloads: 28285
Price: Free* [*Free Regsitration Required]
Uploader: Shat

Subscribe to Instron News! A9338 plot will show where the wire yielded during the twist test, as well as the failure point and profile.

Bluehill Universal Brochure Bluehill Universal Software is built from the ground-up for touch interaction and an intuitive user experience. Additionally, some labs want to know the torque required for specimen failure and would also like to see a plot of torque versus the number of turns for the entire test.

Keyless chucks W-MT01 offer a toothed profile that helps reduce slippage. Discover simpler and smarter testing with features such as pre-loaded test methods, QuickTest in seconds, enhanced data exporting: Onsite Training At Your Facility.

Contact Us View Accessories Catalog. Keyed chucks W-MTB provide smaller diameter clamping. Next Checking to see if you are a returning visitor…. Speed of Twisting – The rate of testing can vary and both standards provide recommended ranges that are based on the wire diameter. WaveMatrix 2 for Dynamic Testing. Total Turns Measurement – The total number of turns to fracture are directly measured by a digital rotary encoder and automatically recorded by the testing software.

  ELECRAFT K2 MANUAL PDF

ASTM A ISO Torsion Testing Wire – Instron

Our MT1 and MT2 torsion test systems offer an axial preload assembly that provides a constant axial force and asgm be adjusted for different size specimens.

Subscribe to Our Newsletters. Both testing standards require that a wire specimen be twisted about the longitudinal axis until it fails. Email addresses must contain the symbol. Concrete, Asphalt and Rock. Lathe style chucks can be supplied for larger diameters and can also be modified to allow for clamping a wire with a 90 degree bend on the ends.

Specimen Lengths – Instron’s MT torsion testers feature an adjustable tailstock assembly that allows for easy adjustment of the test opening.

Upon failure, the number of turns should be recorded. MicroTorsion Series As the preferred solution for low-force torsion testing and component in-service simulation, the MT MicroTorsion Series test wires, fasteners, switches, and springs in the biomedical, automotive, and aerospace industries.

As the preferred solution for low-force torsion testing and component in-service simulation, the MT MicroTorsion Series test wires, fasteners, switches, and springs in the biomedical, automotive, and aerospace industries.

How can we help you? Check this box to receive pertinent commercial email from Instron focusing on products, upcoming events, and more!

Torque versus Rotation plots are automatically generated during the test and indicate where the wire yields and fractures. Bluehill LE for Basic Testing. We use cookies to improve your browsing experience. Tests cannot be run when the door is opened and the rugged Lexan shield helps protect the operator from broken specimen fragments that may be ejected during failure.

Bluehill Universal Software is built from the ground-up for touch interaction and an intuitive user experience. Axial Tensile Force – To prevent the wire from bending away from the axis of rotation, a small tensile load is required to keep the specimen straight during testing.

  BENIHANA OF TOKYO CASE ANALYSIS PDF

Gripping Maintaining the rate of turning Applying a constant tensile force Accommodating various specimen lengths Shielding against broken specimen fragments Automatic turn counting Measuring and plotting torque Instron Solution Gripping – Many common wire diameters can be gripped with standard ashm style chucks.

The MT torsion models are available with extended length if longer specimen lengths are required. The MT torsion systems are supplied with precision torque cells that can measure torque accurately down to 0. Glossary of Materials Testing Terms. Guide rails enable the assembly to move freely in the axial direction while a test is being performed.

Torsion Testing Wire to ASTM A938 and ISO 7800

Users of previous versions of software such as Bluehill 2 and Bluehill 3 can easily upgrade to the newest version of Bluehill. The real-time measurement data can also be plotted graphically during the test. Please confirm that you agree with our privacy and cookies policy to submit this form.

Email addresses can only contain letters, numbers and the following special characters: Software for Series Systems. By continuing to use our site, you accept our cookie policy. Challenges The challenges of testing wire to these standards are: Universal materials testing software for static hydraulic, electromechanical and torsion testing systems – WBB.

admin